Home Company Products Contacts Site map

products

SUPERLOK® Tube fittings > STUB TUBE CONNECTOR > SFA Female Adapter




 

SFA
Female Adapter

     

Connects Fractional SUPERLOK Port To Male NPT Thread


Part No. Tube O.D.D (inch) T* (NPT) d (Min) Width Across Flat h (inch) I L
SFA 2 - 2N 1/8 1/8 2.28 9/16 13.45 31.50
SFA 2 - 4N 1/8 1/4 2.28 3/4 13.45 35.30
SFA 3 - 2N 3/16 1/8 3.04 9/16 14.20 32.00
SFA 3 - 4N 3/16 1/4 3.04 3/4 14.20 35.81
SFA 4 - 2N 1/4 1/8 4.82 9/16 15.75 33.02
SFA 4 - 4N 1/4 1/4 4.82 3/4 15.75 37.10
SFA 4 - 6N 1/4 3/8 4.82 7/8 15.75 39.37
SFA 4 - 8N 1/4 1/2 4.82 1-1/16 15.75 45.50
SFA 5 - 2N 5/16 1/8 6.35 9/16 16.80 34.29
SFA 5 - 4N 5/16 1/4 6.35 3/4 16.80 37.59
SFA 6 - 2N 3/8 1/8 7.11 9/16 17.50 34.29
SFA 6 - 4N 3/8 1/4 7.11 3/4 17.50 38.10
SFA 6 - 6N 3/8 3/8 7.11 7/8 17.50 40.38
SFA 6 - 8N 3/8 1/2 7.11 1-1/16 17.50 46.73
SFA 8 - 4N 1/2 1/4 9.90 3/4 23.20 43.43
SFA 8 - 6N 1/2 3/8 9.90 7/8 23.20 45.46
SFA 8 - 8N 1/2 1/2 9.90 1-1/16 23.20 51.80
SFA 10 - 6N 5/8 3/8 12.70 7/8 24.70 48.26
SFA 10 - 8N 5/8 1/2 12.70 1-1/16 24.70 53.08
SFA 12 - 8N 3/4 1/2 14.98 1-1/16 24.70 52.83
SFA 12 - 12N 3/4 3/4 14.98 1-5/16 24.70 54.86
SFA 12 - 16N 3/4 1 14.98 1-5/8 24.70 58.42
SFA 14 - 12N 7/8 3/4 17.27 1-5/16 26.70 57.15
SFA 16 - 12N 1 3/4 20.32 1-5/16 31.70 60.70
SFA 16 - 16N 1 1 20.32 1-5/8 31.70 64.26
* ISO Tapered Threads are available upon request
 
Connects Metric SUPERLOK Port To Male NPT Thread
 
Part No. Tube O.D.(D) T* (NPT) d (Min) Width Across Flat h (inch) I L
SFA 3M - 2N 3 1/8 1.8 14 13.15 31.2
SFA 6M - 2N 6 1/8 4.6 14 15.75 32.5
SFA 6M - 4N 6 1/4 4.6 19 15.75 37.1
SFA 8M - 4N 8 1/4 6.3 19 16.50 37.6
SFA 10M - 4N 10 1/4 7.7 19 17.50 38.1
SFA 10M - 6N 10 3/8 7.7 22 17.50 40.1
SFA 10M - 8N 10 1/2 7.7 27 17.50 46.5
SFA 12M - 4N 12 1/4 9.1 19 23.50 43.7
SFA 12M - 6N 12 3/8 9.1 22 23.50 46.0
SFA 12M - 8N 12 1/2 9.1 27 23.50 52.3
SFA 18M - 12N 18 3/4 13.9 32 24.90 54.8
* ISO Tapered Threads are available upon request

All dimensions in millimeters unless specified as "inch"
 
SUPERLOK Adapter Solve Alignment Problems
 
1. Required installation is to connect tubing in direction shown, to a female port.   3. To connect this situation, merely tighten pipe thread of male adapter into female port.
     
 
2. With pipe connection tight, the male elbow is pointing the wrong direction for desired tubing run.   4. Connect union elbow to adapter by tightening SUPERLOK connection with wrench while holding elbow pointing in desired direction Then insert tubing into the other end of the Union Elbow and connect tubing